GTI load cell

version
Delivery time 6-7 working days

Hermetically sealed, laser-welded load cell made of stainless steel with high protection against moisture. Particularly suitable for weighing silos and tanks.

Nominal load in kg (Emax)

5000-10000-20000-30000-50000-75000-100000

accuracy class according to OIML R 60

C3

number of division values ​​(nLC)

3000

Nominal characteristic value (Cn) / characteristic value tolerance

2mV/V +/-0.1%

minimum preload (Emin)

0kg

Characteristic value of the relative minimum pitch of the tool (Y = Emax / vmin)

10,000

limit load (EL)

150%

breaking load (Ed)

200%

Recommended supply voltage (Uref)

5-12V

Maximum permissible supply voltage (BU)

15V

zero adjustment

<2%

input resistance (RLC) at reference temperature

766Ω +/-5%

Output resistance (RO) at reference temperature

700Ω +/-5%

insulation resistance

>5000MΩ

cable length

18m

nominal temperature range (BT)

-10 to +40 °C

Protection class according to (DIN 40.050 / EN 60529)

IP68

material

stainless steel