Load cell GTD 2.5...30t
Use this text to encourage communication or promote sharing on social networks.
Stainless steel load cell GTD – Ideal for silos & tanks
The GTD load cell is a hermetically sealed, laser-welded stainless steel load cell with high resistance to moisture and harsh environmental conditions. Thanks to its compact design and particularly low profile, this weight sensor is ideal for weighing silos, tanks, and industrial containers .
With its IP68 protection rating, the GTD load cell offers optimal protection against water and dust—ideal for use in harsh industrial environments or in changing weather conditions. The high-quality stainless steel not only ensures durability but also hygienic conditions, for example, in the food or chemical industries.
With nominal loads of up to 30,000 kg , an accuracy class according to OIML R 60 C1 and a characteristic value of 2 mV/V ±0.02 mV/V , the GTD load cell meets the highest requirements for precision and reliability .
|
Nominal load in kg (Emax) |
2500-3000-5000-7500-10000-12500-20000-25000-30000 |
|
Accuracy class according to OIML R 60 |
C1 |
|
Number of division values (nLC) |
1000 |
|
Nominal characteristic value (Cn) / characteristic value tolerance |
2mV/V +/-0.02mV/V |
|
Minimum preload (Emin) |
0kg |
|
Characteristic value of the relative minimum pitch of the tool (Y = Emax / vmin) |
10000 |
|
Limit load (EL) |
150% |
|
Breaking load (Ed) |
200% |
|
Recommended supply voltage (Uref) |
5-18V |
|
Maximum permissible supply voltage (BU) |
18V |
|
Zero adjustment |
<2% |
|
Input resistance (RLC) at reference temperature |
765Ω +/-15Ω |
|
Output resistance (RO) at reference temperature |
700Ω +/-15Ω |
|
Insulation resistance |
>4000MΩ |
|
Cable length |
8m |
|
Nominal temperature range (BT) |
-10 to +40 °C |
|
Protection class according to (DIN 40.050 / EN 60529) |
IP68 |
|
material |
stainless steel |