load cell G5N

version
Delivery time 6-7 working days

Hermetically sealed, laser-welded load cell made of nickel-plated steel with high protection against moisture (IP68). Particularly suitable for platform scales with 4 load cells and for weighing silos and tanks. The G5N load cells with Emax 2000kg and 3000kg are also available with an input resistance of 1000Ω.

Nominal load in kg (Emax)

300-500-750-1000-1500-2000-2500-3000-5000

accuracy class according to OIML R 60

C3

number of division values ​​(nLC)

3000

Nominal characteristic value (Cn) / characteristic value tolerance

2mV/V +/-1%

minimum preload (Emin)

0kg

Characteristic value of the relative minimum pitch of the tool (Y = Emax / vmin)

10,000

limit load (EL)

125%

breaking load (Ed)

150%

Recommended supply voltage (Uref)

5-12V

Maximum permissible supply voltage (BU)

18V

zero adjustment

<1%

input resistance (RLC) at reference temperature

383 o. 1000Ω +/-2 Ω

Output resistance (RO) at reference temperature

350 or 1000Ω +/-2 Ω

insulation resistance

>5000MΩ

cable length

5m

nominal temperature range (BT)

-10 - +40 °C

Protection class according to (DIN 40.050 / EN 60529)

IP68

material

Nickel-plated steel