Load cell G5N 0.3...5t
Use this text to encourage communication or promote sharing on social networks.
G5N load cell – High-precision, IP68-certified load cell made of nickel-plated steel
Discover the G5N load cell – a robust, laser-welded precision load cell made of nickel-plated steel . Its hermetically sealed design provides optimal protection against moisture, dust, and environmental influences ( IP68 protection rating ). This high-quality load cell is ideal for use in platform scales with four load cells, as well as for weighing tanks and silos .
The G5N series impresses with high measurement accuracy according to OIML R60 C3 , reliable long-term stability, and a wide range of rated loads from 300 kg to 5000 kg . Of particular note is its availability with an input resistance of 1000 Ω , ideal for special applications or modernizations of existing systems.
|
Nominal load in kg (Emax) |
300-500-750-1000-1500-2000-2500-3000-5000 |
|
Accuracy class according to OIML R 60 |
C3 |
|
Number of division values (nLC) |
3000 |
|
Nominal characteristic value (Cn) / characteristic value tolerance |
2mV/V +/-1% |
|
Minimum preload (Emin) |
0kg |
|
Characteristic value of the relative minimum pitch of the tool (Y = Emax / vmin) |
10000 |
|
Limit load (EL) |
125% |
|
Breaking load (Ed) |
150% |
|
Recommended supply voltage (Uref) |
5-12V |
|
Maximum permissible supply voltage (BU) |
18V |
|
Zero adjustment |
<1% |
|
Input resistance (RLC) at reference temperature |
383 or 1000Ω +/-2 Ω |
|
Output resistance (RO) at reference temperature |
350 or 1000Ω +/-2 Ω |
|
Insulation resistance |
>5000MΩ |
|
Cable length |
5m |
|
Nominal temperature range (BT) |
-10 - +40 °C |
|
Protection class according to (DIN 40.050 / EN 60529) |
IP68 |
|
material |
Nickel-plated steel |