Weighing transmitter for control cabinet installation on Omega/DIN rail. With many selectable outputs for connection to bus systems.
- Space-saving, slim design
- Dimensions: 115x25x120 mm
- 6-digit semi-alphanumeric red LED display (8 mm digit height)
- 6 display LEDs
- 4 buttons for system adjustment
- Removable screw terminal blocks
- The instrument can be configured and managed with the free PC software
- Serial interface RS485 for communication via protocols
- ModBus RTU, ASCII Laumas or continuous unidirectional transmission
- 3 relay outputs controlled by setpoints or protocols
- 2 opto-isolated digital PNP inputs: status reading via serial communication protocols
- 1 load cell input
version |
Description |
TLB485 |
Serial interface RS485 Baud rate: 2400, 4800, 9600, 19200, 38400, 115200 (bit/s). |
TLB |
Opto-isolated 16-bit analog output Current signal selectable: 0÷20 mA; 4÷20 mA (up to 300 Ω). Voltage signal selectable: 0÷10 V; 0÷5 V; ±10 V; ±5 V (min 10 kΩ). Equipped with RS485 serial interface. |
TLBCANOPEN |
CANopen interface Baud rate: 10, 20, 25, 50, 100, 125, 250, 500, 800, 1000 (Kbit/s). |
TLBDEVICENET |
DeviceNet interface Baud rate: 125, 250, 500 (Kbit/s). |
TLBCCLINK |
CC-Link interface Baud rate: 156, 625, 2500, 5000, 10000 (Kbit/s). |
TLBPROFI |
Profibus DP interface Baud rate: up to 12 Mbit/s. The instrument works as a slave in a Profibus DP network. Equipped with serial interface RS485. |
TLBMODBUSTCP |
Modbus/TCP interface Type: RJ45 10Base-T or 100Base-TX (auto-sensing). The instrument works as a slave in a Modbus/TCP network. Equipped with serial interface RS485. |
TLBETHETCP |
Ethernet TCP/IP interface Type: RJ45 10Base-T or 100Base-TX (auto-sensing). The instrument operates in an Ethernet TCP/IP network and is also accessible via a web browser. Equipped with a serial interface RS485. |
TLBETHEIPN |
2x Ethernet/IP interfaces Type: RJ45 10Base-T or 100Base-TX (auto-sensing). |
TLBPROFINETION |
2x Profinet IO interfaces Type: RJ45 100Base-TX. |
TLBETHERCAT |
2x EtherCAT interfaces Type: RJ45 10Base-T or 100Base-TX (auto-sensing). |
TLBPOWERLINK |
2x POWERLINK interfaces Type: RJ45 10Base-T or 100Base-TX (auto-sensing). |
TLBSERCOS |
2x SERCOS III interfaces Type: RJ45 10Base-T or 100Base-TX (auto-sensing). |
Technical data
power supply and power consumption |
12÷24 VDC ±10%; 5 W (Use a 12-24 VDC external LPS or protection class 2 power supply) |
Number of load cells • Power supply of the load cells |
up to 8 (350 Ω) - 4/6 conductors • 5 VDC/120 mA |
Linearity • Linearity of the analog output (TLB only) |
<0.01% full scale • <0.01% full scale |
Thermal drift • Thermal drift of the analog output (TLB only) |
<0.0005% full scale/°C • <0.003% full scale/°C |
A/D converter |
24 bit (16000000 digits) - 4.8 kHz |
Calibration values (with measuring range ±10 mV and sensitivity 2 mV/V) |
±999999 • 0.01 μV/d |
measuring range |
±39 mV |
sensitivity of the load cells |
±7 mV/V |
conversion per second |
300/s |
display area |
±999999 |
decimal places • Display resolution |
0÷4 • x1 x2 x5 x10 x20 x50 x100 |
Digital filter • Readings per second |
10 levels • 5÷300 Hz |
relay outputs |
3 - max 115 VAC/150 mA |
Opto-isolated digital inputs |
2 - 5÷24 VDC PNP |
Serial interfaces |
RS485 |
baud rate |
2400, 4800, 9600, 19200, 38400, 115200 (bit/s) |
Opto-isolated analog output (TLB only) |
16 bits = 65535 calibration values. 0÷20 mA; 4÷20 mA (up to 300 Ω) 0÷10V; 0÷5V; ±10V; ±5 V (min 10 kΩ) |
humidity (non-condensing) |
85% |
storage temperature |
-30 °C +80 °C |
operating temperature |
-20 °C +60 °C |
Permit |
EU: 2014/31/UE; OIML R76:2006; EN45501:2015 |
accuracy class |
III or IIII |
Maximum number of division values for the calibration approval |
10000 (Class III); 1000 (Class IIII) |
Minimum input signal for calibration |
0.2 μV/VSI |
The TLP series is also available with 4 load cell inputs. Please inquire!