load cell R30X 1...25t

version
Delivery time 6-7 working days

  • Made of stainless steel 1.4418 for maximum corrosion resistance
  • Hermetically sealed (IP68)
  • High-precision load cell, certified according to 3000d OIML R60
  • Ideal for weighing tanks in humid environments
  • Very easy to clean
  • Optional plug output

rated load (Emax)

1, 2.5, 6, 12, 25 t

accuracy class according to OIML R 60

C3

number of division values ​​(nLC)

3000

Combined error (% Cn)

±0.017%

nominal characteristic value (Cn)

2 ± 0.15% mV/V

input resistance / output resistance

760 ± 20 / 700 ± 5 Ω

permissible limit load

150% Emax

breaking load

300 %Emax

cable length

10 m

nominal temperature range (BT)

-10 … +40 °C

protection class according to EN 60529

IP68, IP69K

material

stainless steel

options

plug outlet