- Load cell made of stainless steel, hermetically welded, protection class IP68
- Accuracy up to ±0.05%
- Spherical load introduction
- Ideal for weighing tanks or silos
- Very easy to clean
- High temperature version (HT: +125°C) on request
- Optional plug output
rated load (Emax) |
0.25, 0.5, 1, 2.5, 5, 10, 15, 30, 50, 100t |
accuracy class according to OIML R 60 |
- |
number of division values (nLC) |
- |
Combined error (% CN) |
±0.2 (0.25t) ±0.1 (0.5t) ±0.05 (1, 2.5, 5, 10t) ±0.1 (15, 30, 50, 100t) |
nominal characteristic value (Cn) |
2 ±0.15 % |
input resistance / output resistance |
730 ±50 / 700 ±10 Ω |
permissible limit load |
0 ... 10 t : 200 / 15 t ... 100 t : 150 % |
breaking load |
0 ... 10 t : 400 / 15 t ... 100 t : 300 % |
cable length |
10 m |
nominal temperature range (BT) |
-10 ... +50 °C |
protection class according to EN 60529 |
IP68, IP69K |
material |
stainless steel |
options |
plug connection ATEX 2014/34/EU, IECEx high-temperature version |