load cell G8R-CP

version
Delivery time 6-7 working days

Hermetically sealed, laser-welded load cell made of stainless steel with maximum protection against moisture (IP69K). Particularly suitable for vehicle scales and for weighing silos and tanks. With integrated surge protection against lightning strikes.

On request also with armoured load cell cable to protect against rodent damage.

Nominal load in kg (Emax)

18000-20000-25000-30000-35000-40000-50000

accuracy class according to OIML R 60

C4

number of division values ​​(nLC)

4000

Nominal characteristic value (Cn) / characteristic value tolerance

2mV/V +/-1%

minimum preload (Emin)

0kg

Characteristic value of the relative minimum pitch of the tool (Y = Emax / vmin)

15,000

limit load (EL)

120%

breaking load (Ed)

150%

Recommended supply voltage (Uref)

10V

Maximum permissible supply voltage (BU)

18V

zero adjustment

<2%

input resistance (RLC) at reference temperature

800Ω +/-2Ω

Output resistance (RO) at reference temperature

700Ω +/-3Ω

insulation resistance

>5000MΩ

cable length

18m

nominal temperature range (BT)

-10 to +40 °C

Protection class according to (DIN 40.050 / EN 60529)

IP69K

material

stainless steel