Load cell G6M 5...40kg
Use this text to encourage communication or promote sharing on social networks.
High-precision stainless steel load cell G6M for platform scales up to 400x400 mm
The stainless steel G6M load cell is the ideal solution for demanding weighing applications requiring high precision – even with eccentric load distribution. Designed for platform sizes up to 400 x 400 mm , this high-quality precision load cell is ideal for use in industrial platform scales , bench scales , checkweighers , and packaging systems .
Available in various nominal capacities (5 kg to 40 kg), the G6M offers the highest accuracy – certified according to OIML R60 in classes C3 (5...15 kg) and C6 (18...40 kg) with up to 6000 division steps (nLC) . Thus, it meets the highest requirements for fine resolution , measurement accuracy , and long-term stability .
|
Nominal load in kg (Emax) |
5-10-15-18-20-25-30-35-40 |
|
Accuracy class according to OIML R 60 |
C3 (Vers. 5,10,15kg) C6 (Vers. 18,20,25,30,35,40kg) |
|
Number of division values (nLC) |
3000 (Vers. 5,10,15kg) 6000 (Vers. 18,20,25,30,35,40kg) |
|
Nominal characteristic value (Cn) / characteristic value tolerance |
2mV/V +/-0.1% |
|
Minimum preload (Emin) |
0kg |
|
Characteristic value of the relative minimum pitch of the tool (Y = Emax / vmin) |
7690 (Vers. 5,10,15kg) 11500 (Vers. 18,20,25,30,35,40kg) |
|
Limit load (EL) |
150% |
|
Breaking load (Ed) |
200% |
|
Recommended supply voltage (Uref) |
10V |
|
Maximum permissible supply voltage (BU) |
15V |
|
Zero adjustment |
<2% |
|
Input resistance (RLC) at reference temperature |
386Ω +/-10% |
|
Output resistance (RO) at reference temperature |
350Ω +/-10% |
|
Insulation resistance |
>5000MΩ |
|
Cable length |
5 |
|
Nominal temperature range (BT) |
-10 to +40 °C |
|
Protection class according to (DIN 40.050 / EN 60529) |
IP66 |
|
material |
stainless steel |
|
Maximum platform size |
400x400mm |