load cell AVX 7.5...125kg
Use this text to encourage communication or promote sharing on social networks.
Stainless steel AVX load cell – precision for demanding applications
The AVX load cell, with a load range of 7.5 to 125 kg , impresses with its high-quality stainless steel construction and was specially developed for use in humid and hygiene-critical environments . Thanks to its hermetically sealed design, it meets protection classes IP68 and IP69K , making it ideal for industrial scales, filling systems, dosing machines , and packaging machines in the food and pharmaceutical industries, as well as in wet production areas .
The AVX load cell is legal for trade up to 6000 parts according to OIML R60 , enabling highly precise weight measurement in professional applications. Thanks to the integrated side load compensation, measurement accuracy remains stable even under lateral forces – a significant advantage in dynamic applications.
|
Nominal load (Emax) |
7.5, 15, 30, 75,125 kg |
|
Accuracy class according to OIML R 60 |
C3: 7.5, 15, 30, 75, 125kg C5: 125 kg C6: 15, 30, 75 kg |
|
Number of division values (nLC) |
3000: 7.5, 15, 30, 75, 125kg 5000: 125 kg 6000: 15, 30, 75 kg |
|
Combined error (% Cn) |
±0.017 %Cn at C3 ±0.01 %Cn at C5 ±0.008 %Cn at C6 |
|
Nominal value (Cn) |
1.8 ±10% (7.5 kg), (option 1.96 ±0.1%) mV/V |
|
Input resistance / output resistance |
385 ±20 / 350 ±5 (option 350 ±0.3) Ω |
|
Permissible limit load |
150% Emax |
|
Breaking load |
300% Emax |
|
Cable length |
3 m |
|
Nominal temperature range (BT) |
+10 ... +40 °C |
|
Protection class according to EN 60529 |
IP68 / IP69K |
|
material |
stainless steel |
|
Maximum platform size |
≤ 30 kg : 500 x 400 / ≥ 75 kg : 600 x 400 mm |
|
Options |
Plug connection - signal output |