load cell AVX 7.5...125kg

version
Delivery time 6-7 working days

  • Stainless steel construction, hermetically sealed (IP68, IP69K)
  • verifiable up to 6000 parts according to OIML R60
  • Ideal for scales and dosing machines in wet environments
  • side load compensated
  • Optional connector
  • Optionally calibrated output signal

rated load (Emax)

7.5, 15, 30, 75,125 kg

accuracy class according to OIML R 60

C3: 7.5, 15, 30, 75, 125kg

C5: 125 kg

C6: 15, 30, 75 kg

number of division values ​​(nLC)

3000: 7.5, 15, 30, 75, 125kg

5000: 125 kg

6000: 15, 30, 75 kg

Combined error (% Cn)

±0.017 %Cn at C3

±0.01 %Cn at C5

±0.008 %Cn at C6

nominal characteristic value (Cn)

1.8 ±10% (7.5 kg), (option 1.96 ±0.1%) mV/V

input resistance / output resistance

385 ±20 / 350 ±5 (option 350 ±0.3) Ω

permissible limit load

150% Emax

breaking load

300% Emax

cable length

3 m

nominal temperature range (BT)

+10 ... +40 °C

protection class according to EN 60529

IP68 / IP69K

material

stainless steel

Maximum platform size

≤ 30 kg : 500 x 400 / ≥ 75 kg : 600 x 400 mm

options

connector - signal output