- load cell made of aluminum, protection class IP65
- Approved up to 3 000 d OIML R60 and 5 000 d NTEP
- Very compact design, ideal for the construction of platform scales
- Permissible platform size 350x350 mm
rated load (Emax) |
5, 10, 15, 20, 35 kg |
accuracy class according to OIML R 60 |
C3 |
number of division values (nLC) |
3000 |
Combined error (% Cn) |
±0.017 %Cn |
nominal characteristic value (Cn) |
2 ±10 % mV/V |
input resistance / output resistance |
410 ±20 / 350 ±5 Ω |
permissible limit load |
150% Emax |
breaking load |
200% Emax |
cable length |
0.5 m |
nominal temperature range (BT) |
-10 ... +40 °C |
protection class according to EN 60529 |
IP65 |
material |
aluminum |
Maximum platform size |
350 x 350 mm |
options |