- load cell made of aluminum, protection class IP65
- Approved up to 6,000 d OIML R60 and 5,000 d NTEP from 5 to 100 kg
- Compensated corner load error
- Ideal for platform scales and dosing scales
rated load (Emax) |
18, 36, 50, 75, 100 kg |
accuracy class according to OIML R 60 |
C6 |
number of division values (nLC) |
6000 |
Combined error (% Cn) |
±0.008 %Cn (C6) |
nominal characteristic value (Cn) |
2 ±10 % mV/V |
input resistance / output resistance |
410 ±15 / 350 ±5 Ω |
permissible limit load |
150% Emax |
breaking load |
200% Emax |
cable length |
3 m |
nominal temperature range (BT) |
-10 ... +40 °C |
protection class according to EN 60529 |
IP65 |
material |
aluminum |
Maximum platform size |
400 x 400 mm |
options |
ATEX 2014/34/EU, IECEx |