- Digital load cell, made of stainless steel, welded IP68
- Approved up to 5,000 d OIML R60
- Digital output RS485
- load cell with self-centering, round bottom
- Ideal for bridge scales
- rodent protection as standard (AR)
- Integrated ESD protection
- Integrated lightning protection in DLCJB box
rated load (Emax) |
20, 30, 40, 60 t |
accuracy class according to OIML R 60 |
C4 |
number of division values (nLC) |
4000 |
Combined error (% Cn) |
±0.014 %Cn |
nominal characteristic value (Cn) |
200,000 digits |
input resistance / output resistance |
- |
permissible limit load |
150% Emax |
breaking load |
300 %Emax |
cable length |
15 m |
nominal temperature range (BT) |
-10 ... +40 °C |
protection class according to EN 60529 |
IP68 |
material |
stainless steel |
options |
C5 version |